Illustrative power generation scene

ALKA · AUSTRALIAN COATINGS MANUFACTURER

Power Generation

Protect structural and service assets across generation facilities.

SERVICE & APPLICATIONS

Protection matched to the asset.

Generation sites contain external structures, internal plant steel and wet-service assets. ALKA systems support atmospheric protection and maintenance for these surfaces, with separate assessment for process temperature and specialist equipment duties.

External steel

Exposed frames, platforms and supports need protection matched to weather and local corrosion conditions.

Internal service steel

Mild-to-moderate atmospheric areas can use a practical epoxy maintenance build.

Wet utility areas

Pump bases, sumps and selected water-service surfaces need substrate and exposure-specific barrier selection.

ALKYD PRIMERS · ENAMELS · SINGLE-PACK FINISHING

Single-pack finishes for ambient-temperature service assets

Prepared cabinet exteriors, dry equipment supports, workshop parts and ancillary frames at ambient service temperatures may suit single-pack primers and enamels. The finishing requirement should be distinguished from hot plant, cooling-water exposure and other demanding generation duties.

Products to assess for the job

Select a complete, compatible primer and finish. The products above are options by role, not a blanket approval to combine every primer and topcoat.

What the applicator or specifier needs

01 · Define the component and duty

Record actual surface temperature, condensation, cleaning and cooling-water exposure by component. Separate the requirements for identification and finish from operating duty.

02 · Prepare and prove compatibility

Prepare around edges, welds and enclosure details without coating labels, seals or functional interfaces. Check old-paint compatibility before maintenance recoating.

03 · Plan handling and return to service

Allow the specified handling and full-cure periods before assembly or service. Include installation damage and subsequent touch-up in the coating schedule.

Write a usable coating schedule

Specify the substrate and preparation, exact primer and finish, individual-coat dry-film thickness, application method, thinning limits, recoat interval and service-cure requirement from current product data. For repainting, document the retained coating and a representative compatibility trial before full application.

Choose the coating for the exposure

Hot surfaces, continuous cooling-water exposure, chemical treatment areas and immersion require purpose-selected systems.

A single-pack route can simplify small batches and routine repainting because it does not require mixing a separate hardener. It still depends on sound preparation, suitable film build and the correct recoat window. Where exposure or the required maintenance interval is more demanding, assess the relevant two-pack epoxy, polyurethane or specialist lining system.

Does fast drying mean the part is ready for service?

No. Touch-dry, recoatable, handleable and fully cured describe different stages. Use the selected product data and actual application conditions to plan each stage. Excessive film build, early overcoating or premature handling can compromise the finish; adding extra thinner or a hardener is not a substitute for the specified application procedure.

SELECT THE COMPLETE BUILD

ALKA systems for this application.

SystemWhy select itCoating buildTotal DFT
ALKA-9930
Premium External
Premium corrosion protection combined with a UV-stable, colour-retentive finish

Abrasive-blasted carbon steel; external industrial and coastal atmospheric exposure

Alka 404 zinc-rich epoxy primer → Alka 413 high-build epoxy → Alka 421 polyurethane finish250–300 µm
ALKA-9940
Economical Maintenance
Cost-effective protection for routine maintenance where exposure is not severe

Prepared steel in mild to moderate industrial atmospheric conditions

Alka 416 single-pack epoxy coating → Alka 412 or Alka 413 maintenance epoxy200–250 µm
ALKA-9935
Glass-Flake Barrier Lining
High-build glass-flake barrier delivers strong resistance to permeation, wet service and abrasion

Prepared steel or concrete exposed to wet service, abrasion, splash, spillage or aggressive industrial conditions

Substrate-specific primer where required → Alka 414 Glass Flake Epoxy → optional approved build or finish coat400–750 µm

DFT = dry-film thickness. These are nominal system totals; individual-coat thicknesses and application conditions belong in the final coating schedule.

SPECIFICATION & APPLICATION

From surface preparation to return to service.

Build the coating schedule around the substrate and the work that can be achieved on site. For refurbishment, assess the adhesion and compatibility of retained coatings before defining repair boundaries.

  • 01Coated-surface temperature
  • 02Internal and external zones
  • 03Water and chemical exposure
  • 04Outage and inspection access

Record surface preparation, environmental conditions, coverage at details and coat thickness. Allow for the specified recoat and cure periods, then inspect and repair defects before release to service.

ALKA-9930 · External steel example

ALKA 421 polyurethane finishExternal colour and finish retention
ALKA 413 high-build epoxyIntermediate barrier protection
ALKA 404 zinc-rich epoxy primerCorrosion protection on prepared steel
Prepared carbon steelClean, profiled substrate and treated details

Schematic, not to scale. Follow the selected system for products, layer count and thickness.

TECHNICAL QUESTIONS

Details that affect system selection.

How should temperature be described in a coating enquiry?

Provide the temperature at the coated surface, including startup, shutdown and cycling. Ambient air temperature alone does not define the duty of equipment near a heat source.

What belongs in the final technical submission?

Include current TDS and SDS, substrate preparation, the product and thickness schedule, application conditions, inspection criteria and cure requirements. For chemical or immersed service, include written suitability for the actual exposure. Any required certification or durability commitment must be supported by the relevant evidence.

Application boundaries

Boilers, exhausts, hot pipework, turbine internals, electrical insulation and nuclear qualification are outside a general protective-paint selection. Record specialist requirements separately.

MANUFACTURER TECHNICAL SUPPORT

Turn the service conditions into a coating specification.

Send the asset, substrate, exposure and maintenance window. ALKA can help define the coating build, preparation and technical documentation for your review.

Discuss your specification

Use current product data and the agreed project specification. Industry imagery is illustrative and does not represent a completed ALKA project.