Illustrative oil & gas scene

ALKA · AUSTRALIAN COATINGS MANUFACTURER

Protective coatings for oil and gas facilities

Coating systems for exposed steel, maintenance and containment.

SERVICE & APPLICATIONS

Protection matched to the asset.

Oil and gas facilities combine weather-facing structures, process equipment and areas exposed to liquids. ALKA system selection separates atmospheric protection from maintenance and chemical lining, helping the coating schedule reflect the actual duty of each asset.

Structural steel

Pipe racks, supports and access structures need primer, barrier and finish selection for the local atmosphere.

Maintenance assets

The surface-tolerant MIO glass-flake route addresses demanding refurbishment with substrate-specific preparation.

Containment

Tank and bund linings depend on the stored or spilled material, temperature and exposure duration.

ALKYD PRIMERS · ENAMELS · SINGLE-PACK FINISHING

Single-pack options for selected ancillary site steel

Workshop items, dry equipment covers and sheltered service frames may have an ordinary atmospheric finishing requirement even within an oil and gas facility. For these identified components, single-pack primers and enamels can be considered alongside the separately specified protection for process assets.

Products to assess for the job

Select a complete, compatible primer and finish. The products above are options by role, not a blanket approval to combine every primer and topcoat.

What the applicator or specifier needs

01 · Define the component and duty

Map hydrocarbon contact, chemical cleaning, insulation and surface temperature before choosing a finish. Asset location alone does not establish suitability.

02 · Prepare and prove compatibility

Identify old coatings and contamination, then agree cleaning, preparation and primer compatibility. Detail welds and connections within the repair boundaries.

03 · Plan handling and return to service

Plan application and cure around the site work controls and shutdown. Record products and repair areas so subsequent maintenance follows the agreed schedule.

Write a usable coating schedule

Specify the substrate and preparation, exact primer and finish, individual-coat dry-film thickness, application method, thinning limits, recoat interval and service-cure requirement from current product data. For repainting, document the retained coating and a representative compatibility trial before full application.

Choose the coating for the exposure

Fuel contact, immersion, containment, corrosion under insulation and hot process surfaces require their own approved systems.

A single-pack route can simplify small batches and routine repainting because it does not require mixing a separate hardener. It still depends on sound preparation, suitable film build and the correct recoat window. Where exposure or the required maintenance interval is more demanding, assess the relevant two-pack epoxy, polyurethane or specialist lining system.

Does fast drying mean the part is ready for service?

No. Touch-dry, recoatable, handleable and fully cured describe different stages. Use the selected product data and actual application conditions to plan each stage. Excessive film build, early overcoating or premature handling can compromise the finish; adding extra thinner or a hardener is not a substitute for the specified application procedure.

SELECT THE COMPLETE BUILD

ALKA systems for this application.

SystemWhy select itCoating buildTotal DFT
ALKA-9930
Premium External
Premium corrosion protection combined with a UV-stable, colour-retentive finish

Abrasive-blasted carbon steel; external industrial and coastal atmospheric exposure

Alka 404 zinc-rich epoxy primer → Alka 413 high-build epoxy → Alka 421 polyurethane finish250–300 µm
ALKA-9937
Severe Maintenance
Combines surface tolerance, high build and glass-flake barrier performance for demanding maintenance work

Prepared steel, galvanised steel, aluminium or stainless steel in difficult maintenance environments, subject to technical approval

Alka 418 MIO glass-flake surface-tolerant epoxy; one or two coats as specifiedNominal 250–600 µm depending on coat schedule
ALKA-9936
Chemical-Resistant Lining
Higher chemical resistance than standard epoxy systems for demanding process environments

Prepared steel or concrete in tanks, bunds, process areas and secondary containment

Alka Tanklin 100 and/or Alka Tanklin Chem system selected to suit the chemical service450–600 µm

DFT = dry-film thickness. These are nominal system totals; individual-coat thicknesses and application conditions belong in the final coating schedule.

SPECIFICATION & APPLICATION

From surface preparation to return to service.

Build the coating schedule around the substrate and the work that can be achieved on site. For refurbishment, assess the adhesion and compatibility of retained coatings before defining repair boundaries.

  • 01Atmospheric and process zones
  • 02Operating temperature range
  • 03Existing coating and preparation
  • 04Chemical contact and shutdown window

Record surface preparation, environmental conditions, coverage at details and coat thickness. Allow for the specified recoat and cure periods, then inspect and repair defects before release to service.

ALKA-9930 · External steel example

ALKA 421 polyurethane finishExternal colour and finish retention
ALKA 413 high-build epoxyIntermediate barrier protection
ALKA 404 zinc-rich epoxy primerCorrosion protection on prepared steel
Prepared carbon steelClean, profiled substrate and treated details

Schematic, not to scale. Follow the selected system for products, layer count and thickness.

TECHNICAL QUESTIONS

Details that affect system selection.

Can a single system cover every oil and gas asset?

No. Atmospheric steel, hot or insulated equipment and tank internals face different conditions. Divide the facility into coating duties and identify which require specialist test evidence before selecting products.

What belongs in the final technical submission?

Include current TDS and SDS, substrate preparation, the product and thickness schedule, application conditions, inspection criteria and cure requirements. For chemical or immersed service, include written suitability for the actual exposure. Any required certification or durability commitment must be supported by the relevant evidence.

Application boundaries

High heat, corrosion under insulation, passive fire protection, cryogenic exposure and offshore qualification are separate performance requirements. The listed systems do not establish those approvals.

PRODUCTS & TECHNICAL DOCUMENTS

Go directly to the product information.

Read the published technical data sheets below, or open a product overview. Request the current SDS set and confirm the document revisions for your specification before procurement.

MANUFACTURER TECHNICAL SUPPORT

Turn the service conditions into a coating specification.

Send the asset, substrate, exposure and maintenance window. ALKA can help define the coating build, preparation and technical documentation for your review.

Discuss your specification

Use current product data and the agreed project specification. Industry imagery is illustrative and does not represent a completed ALKA project.